Sprinkler protection for water-sensitive environments where accidental discharge is not an option. Designed to NFPA 13 by FML.

Designed to NFPA 13 Standard
How It Works

Protection Built for Water Sensitive Areas

A pre-action system holds water back until two independent events confirm a fire — first, a detection device activates; then, a sprinkler head reaches its threshold. Both conditions must be met before water discharges. Pipe failure, a mechanically failed head, or a false alarm cannot trigger the system on their own.

FML designs and installs pre-action systems to NFPA 13 for data centres, healthcare facilities, archives, and any environment where the consequences of accidental water damage rival the consequences of fire itself.

1
Detection device activates

A detection device confirms smoke, heat, or flame. The pre-action valve opens and water fills the pipes.

2
Sprinkler head activates

A sprinkler head reaches its activation threshold. Water discharges — only at the point of fire.

NFPA 13 Design Standard
Dual Activation Required
Dry Pipe At Rest
What to Expect

What an FML Installation Involves

Site Assessment

Our engineers assess your facility and determine the right configuration — single or double interlock — based on your environment and risk profile.

  • Environment sensitivity review
  • Detection system compatibility
  • Interlock configuration selection
  • NFPA 13 hazard classification

System Design

Hydraulic calculations, pipe layout, pre-action valve specification, and detection system integration schematics. Reviewed and approved before installation begins.

  • Hydraulic and pipe layout design
  • Pre-action valve specification
  • Detection system integration schematic
  • Regulatory submission documentation

Installation

Dry pipework, sprinkler heads, pre-action valve assembly, and detection integration installed by FML’s own team. Phased installation available for live environments.

  • Dry pipework and sprinkler head installation
  • Pre-action valve and control panel assembly
  • Detection device integration
  • Phased installation for live environments

Testing and Commissioning

Full detection-to-suppression sequence testing. We verify every trigger point — no live discharge into the protected area.

  • Detection trigger and valve response test
  • Pipe pressurisation verification
  • Sprinkler head integrity checks
  • Alarm and control panel function test

Certification and Handover

NFPA 13 compliance, as-built drawings, valve maintenance schedule, and a handover briefing covering routine checks and emergency reset procedures.

  • NFPA 13 compliance
  • As-built drawings and documentation
  • Valve maintenance schedule
  • Facilities team handover and reset briefing

Ready to get your facility assessed?

Site assessments are free. Our engineers will evaluate your environment and confirm whether pre-action is the right system for your needs.
Request a Site Assessment
Ready to Install?

Get a System
Designed
for Your Building

Tell us about your building, your system, or your challenge. Our team will assess your needs and recommend the right solution.

Request a Quote +1 (868) 665-1503

24-hour emergency service available.
Call us any time for critical system faults.